# Troubleshooting Guide

If your Loncel device is not behaving as expected, follow these general troubleshooting steps.

## Communication Issues

### Device Offline in Cloud
If a device appears "Offline" on the Loncel Cloud dashboard:

### WVC-LTE

1. **Check Power:** Ensure the device has power.
2. **Check Signal LEDs:** Observe the status LEDs on the device.
   - **Green:** Connected.
   - **Red:** Disconnected.
3. **Inspect Antennas:** Ensure all antennas (LTE, 915MHz) are securely tightened and have a clear line-of-sight if applicable.
4. **Reboot:** Power cycle the device by disconnecting the power for 10 seconds and reconnecting.

### WVC-GS

1. **Check Battery:** Verify battery voltage (should be \~3.6V). WVC-GS radios use a high-capacity 8500mAh Li-SOCl2 battery. Voltages below 3.3V are considered low and may cause radio faults.
2. **Line of Sight:** Ensure there is no excessive foliage or new obstacles between the radio and the Base/Repeater.
3. **Inspect Hardware:** Check for damage caused by livestock or extreme weather (lightning, intense rain).
4. **Ping Test:** Use the **Ping** function in the dashboard to manually trigger a communication test.

### RMU

1. **Check Power:** Ensure the RMU is connected to a stable power source.
2. **Check LTE Connection:** Press the Test button on the RMU to initiate a manual data transmission and show the system status menu.
3. **Reboot:** Power cycle the device by disconnecting the power for 10 seconds and reconnecting.

## Sensor & Valve Issues

### Analog Input (4-20mA) Reading 0
If your RMU or Gateway is reading 0mA for a sensor:

1. **Check Wiring:** Verify the sensor is wired correctly to the terminal blocks.
2. **Measure Loop Current:** Use a multimeter to verify if the sensor is actually outputting a current.
3. **verify Power:** Ensure the 4-20mA loop has the required excitation voltage (usually provided by the RMU or an external supply).

### Valve Not Opening
If a WVC-GS Valve Radio is not triggering a solenoid:

1. **Manual Override:** Try to trigger the valve manually via the Loncel Cloud interface to rule out scheduling issues.
2. **Check Solenoid:** Inspect the wiring to the latching solenoid. Ensure the solenoid is a DC latching type compatible with the radio output.
3. **Check Signal Strength:** Verify the radio has a strong link to the Base or Repeater radio.

## Still Need Help?

If you cannot resolve the issue, please contact Loncel Support with the following info:
- Device Serial Number (found on the label).
- A description of the status LEDs.
- Site location and any recent weather events or power outages.